Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Zhonghua Wai Ke Za Zhi ; 50(6): 560-5, 2012 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-22943954

RESUMO

OBJECTIVES: To establish the animal model of acute rotator cuff tear in rabbits, and study the effect of timing of surgical repair on healing of tendon-bone interface, formation and distribution of collagens in the supraspinatus tendon insertion and biomechanical properties of supraspinatus. METHODS: Supraspinatus tenotomy was performed in the right shoulder of 90 skeletally matured male New Zealand white rabbits to establish the animal model of acute rotator cuff tear. The rabbits were randomly divided into 3 groups : group of early repair, repaired at 1 week after tenotomy; group of late repair, repaired at 4 weeks after tenotomy; and group without repair, used as control. At 2 weeks, 4 weeks and 8 weeks after repair, healing of tendon-bone interface was observed by HE staining. Collagens were observed by Sirius Red F 3B (SR) in saturated carbazotic acid staining. The areas of type I and III collagens were measured by using imaging analysis software and the ratio of type I and III collagens were calculated. Failure loads of supraspinatus on both sides were measured. The percentage of failure loads of the surgical side was calculated and contralateral supraspinatus were uninjured. RESULTS: There was no obvious fatty infiltration and muscle atrophy in supraspinatus in all groups. At 8 weeks, the formation of a new enthesis of supraspinatus in groups of early and late repair were observed. In groups of early and late repair, the ratio of areas of type I and III collagens at 8 weeks (2.02 ± 0.77 and 2.06 ± 0.58) was larger than that at 2 weeks (1.10 ± 0.24 and 1.14 ± 0.50, t = 3.082, 3.655, P < 0.01). At 2, 4 and 8 weeks, the percentages of failure loads of the surgical side and uninjured contralateral supraspinatus in group of early repair(38% ± 11%, 66% ± 7%, 89% ± 4%) and group of late repair (41% ± 16%, 63% ± 7%, 89% ± 9%) were both higher than that in group without repair (14% ± 6%, 32% ± 4%, 56% ± 12%); the differences were all statistically significant (group of early repair: t = 3.311, 8.549, 5.719; group of late repair: t = 3.713, 8.063, 6.044; P < 0.01). The percentage of failure loads of the surgical side and uninjured contralateral supraspinatus at 8 weeks was higher than those at 4 weeks (t = 3.878 - 4.613, P < 0.01) and 2 weeks (t = 7.158 - 10.024, P < 0.01) in all groups. CONCLUSIONS: Surgical repair within 4 weeks of acute rotator cuff tear lead to formation of a new enthesis of supraspinatus, improvement of both ratio of type I collagen in the supraspinatus tendon insertion and biomechanical properties of supraspinatus.


Assuntos
Lesões do Manguito Rotador , Animais , Fenômenos Biomecânicos , Colágeno Tipo I/metabolismo , Colágeno Tipo III/metabolismo , Modelos Animais de Doenças , Masculino , Coelhos , Manguito Rotador/patologia , Manguito Rotador/cirurgia , Fatores de Tempo
2.
Zhonghua Wai Ke Za Zhi ; 48(8): 606-9, 2010 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-20646479

RESUMO

OBJECTIVE: To study the biomechanical characteristics of antegrade intramedullary fixation for metacarpal fractures. METHODS: From March to May 2008, both the 4th and 5th metacarpals from 25 formalin embalmed cadaver hands had three-point bending test after transverse osteotomy followed by randomly fixation with one of the following three methods: plate and screw, antegrade intramedullary K-wire, crossed K-wire. While, both the 2nd and 3rd metacarpals had torsional loading test after the same management as the 4th and 5th metacarpal had undergone. RESULTS: In the three-point bending test, both the maximum bending moment (M(max)) and bending rigidity (EI) of the antegrade intramedullary K-wire were comparable with those of the plate and screw, and were significantly larger than those of the crossed K-wire. In the torsional loading test, the antegrade intramedullary K-wire had a statistically smaller maximum torque (T(max)) than the plate and screw, and had a comparable T(max) with the crossed K-wire; while, the torsional rigidity (GJ) of the intramedullary K-wire was statistically weaker than that of both the plate and screw and the crossed wire. CONCLUSIONS: One single antegrade intramedullary K-wire can provide a satisfactory M(max) and EI for metacarpal fixation and shows relatively weak in the torsional loading test. The injured finger should be well protected to avoid torsional deformity in clinical practice.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Ossos Metacarpais/lesões , Adulto , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Fios Ortopédicos , Cadáver , Fixação Interna de Fraturas/instrumentação , Humanos , Osteotomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...